New series of air cooled chillers

Feel free to contact us:

+371 27009306

+371 29166263

This email address is being protected from spambots. You need JavaScript enabled to view it. 

   WATER water-cooled water chillers do not need to be placed outside, as they do not need outside air. They can be located in the premises. This is a very important factor, since sometimes there is no elementary large space to accommodate an air-cooled chiller. And this is where water cooled chillers come to the rescue.

   Small size and the lack of need for outdoor air allows you to install them inside buildings. Obvious plus internal placement of chillers - the ability to use clean water as a coolant. This greatly simplifies the operation of the entire system, improves its efficiency, reduces the corrosive effect on pipelines and valves, and improves the environmental friendliness of the system.

   Water cooled chillers with condensers or with external condensers are designed to serve small and medium commercial and industrial systems. Compact and easy installation - the key advantages of the units of this serie

In accordance with standard Eurovent LCP/A/P/C/AC, water Tint/Tout 12/7 °C, external air T=35 °C

Unit dimensions may be altered taking into consideration customer’s wishes, or also if such changes are required by the producer.

Scroll

compressors

 

Axial fan

Refrigerant

R410A

 

Soldered plastic

 heat exchangers

 

 Cooling agent specific output, kW

32 WCDS-30 40 WCDS-40 54 WCDS-55 71 WCDS-70 95 WCDS-95 109 WCDS-110

 Consumed power, kW/

 6.5 WCDS-30 8.4 WCDS-40 11.2 WCDS-55 14.4 WCDS-70 19.7 WCDS-95 22.8 WCDS-110

 EER

4.94 WCDS-30 4.94 WCDS-40 4.89 WCDS-55 4.94 WCDS-70 4.83 WCDS-95 4.79 WCDS-110

 EBEER

WCDS-30 B WCDS-40 B WCDS-55 B WCDS-70 WCDS-95 B  WCDS-110

 Water volume

2,9 WCDS-30  4,1 WCDS-40  7,5 WCDS-55 7,5 WCDS-70 9,9 WCDS-95 12,3 WCDS-110

 Minimum flow rate, m3/h

 3.3 WCDS-30 4.1 WCDS-40 5,6 WCDS-55 7,3 WCDS-70 9,8 WCDS-95  11,2 WCDS-110

 Maximum flow rate, m3/h

9 WCDS-30 11 WCDS-40 16 WCDS-55 20 WCDS-70 27 WCDS-95 31 WCDS-110

 DN

42 WCDS-30 42 WCDS-40 42 WCDS-55 50 WCDS-70 50 WCDS-95 65 WCDS-110

 dPw, kP

26 WCDS-30 22 WCDS-40 26 WCDS-55 30 WCDS-70 34 WCDS-95 20 WCDS-110

 Water volume

2,9 WCDS-30 4,1 WCDS-40 7,5 WCDS-55 7,5 WCDS-70 9,9 WCDS-95 12,3 WCDS-110

 Minimum flow rate, m3/h

3,7 WCDS-30 4,7 WCDS-40 6,4 WCDS-55 8,3 WCDS-70 11,1 WCDS-95 12,8 WCDS-110

 Maximum flow rate, m3/h

 10,3 WCDS-30 12,9 WCDS-40 17,6 WCDS-55 22,8 WCDS-70 30,6 WCDS-95 35,1 WCDS-110

 DN

42 WCDS-30  42 WCDS-40  42 WCDS-55 50  WCDS-70 50 WCDS-95 65 WCDS-110

 dPw, kP

24 WCDS-30  28 WCDS-40 33 WCDS-55 30 WCDS-70 20 WCDS-95 19 WCDS-110

Options

Crankcase

heater

 

High pressure

low pressure

protection sensors

PUMP DOWN

systems

 

Fan control

via pressure

sensors

Fan rotation

speed regulator

 

High pressure and

low pressure

manometers

Acoustic

insulation

Multi-contact

connector

EC fans

 

Stand-alone low

pressure pump

Pump inverter

 

Tank

 

1. a tandem of scroll compressors  

2. condenser fan

3. condenser

4. filter-drie

5. moisture indicator

6. thermally controlled valve

7. evaporator

8. low pressure sensor

9. high pressure sensor

10. other sensors

AirTop

AirTwin

AirTwin

WaterBox

WaterBox

AirV-plus

AirV-plus